Introduction
Introduction
The motor works because, simply put, when a current is passed through the motor circuit, there is a reaction between the current in the field and the current in the armature which causes the armature to turn. The armature and the field are connected in series and the whole motor is referred to as "series wound".A series wound DC motor has a low resistance field and armature circuit. Because of this, when voltage is applied to it, the current is high. (Ohms Law: current = voltage/resistance). The advantage of high current is that the magnetic fields inside the motor are strong, producing high torque (turning force), so it is ideal for starting a train. The disadvantage is that the current flowing into the motor has to be limited somehow, otherwise the supply could be overloaded and/or the motor and its cabling could be damaged. At best, the torque would exceed the adhesion and the driving wheels would slip. Traditionally, resistors were used to limit the initial current. DC Resistance Control As the DC motor starts to turn, the interaction of the magnetic fields inside it causes it to generate a voltage internally. This "back voltage" opposes the applied voltage and the current that flows is governed by the difference between the two. So, as the motor speeds up, the internally generated voltage rises, the effective voltage falls, less current is forced through the motor and thus the torque falls. The motor naturally stops acceleratingwhen the drag of the train matches the torque produced by the motors. To continue accelerating the train, resistors are switched out in steps, each step increasing the effective voltage and thus the current and torque for a little bit longer until the motor catches up. This can be heard and felt in older DC trains as a series of clunks under the floor, each accompanied by a jerk of acceleration as the torque suddenly increases in response to the new surge of current. When no resistor is left in the circuit, the full line voltage is applied directly to the motor. The train's speed remains constant at the point where the torque of the motor, governed by the effective voltage, equals the drag - sometimes referred to as balancing speed. If the train starts to climb a grade, the speed reduces because drag is greater than torque. But the reduction in speed causes the back voltage to decline and thus the effective voltage rises - until the current forced through the motor produces enough torque to match the new drag. On an electric train, the driver originally had to control the cutting out of resistance manually but, by the beginning of the First World War in 1914, automatic acceleration was being used in the UK on multiple-unit trains. This was achieved by an accelerating relay (often called a "notching relay") in the motor circuit (see next diagram below) which monitored the fall of current as each step of resistance was cut out. All the driver had to do was select low, medium or full speed (called "shunt", "series" and "parallel" from the way the motors were connected in the resistance circuit) and the equipment would do the rest. Motor Control and Protection As we have seen, DC motors are controlled by a "notching relay" set into the power circuit. But there are other relays provided for motor protection. Sharp spikes of current will quickly damage a DC motor so protective equipment is provided in the form of an "overload relay", which detects excessive current in the circuit and, when it occurs, switches off the power to avoid damage to the motors. Power is switched off by means of Line Breakers, one or two heavy-duty switches similar to circuit breakers which are remotely controlled. They would normally be opened or closed by the action of the driver's controller but they can also be opened automatically by the action of the overload relay.On a historical note, early equipment (pre-1905) had a huge fuse instead of an overload relay. Some of these lasted into the 1970s and I recall the complications of changing one, which involved inserting a wooden board (called a "paddle") between the shoes and the current rail. This was to isolate the current from the locomotive while you changed the fuse.A further protective device is also provided in the classic DC motor control circuit. This is the "no-volt" relay, which detects power lost for any reason and makes sure that the control sequence is returned to the starting point (i.e. all the resistances are restored to the power circuit) before power could be re-applied. This is necessary to ensure that too much current is not applied to a motor which lost speed while current was off. DC Power Circuit This diagram shows a simple traction motor power control circuit. Most DC motor circuits are arranged to control two or four motors. The control range is enhanced by changing the connections to the motors as the train accelerates. The system is known as "series-parallel control". Series-Parallel Control This diagram shows the principle of series-parallel control. There are three stages, "series", "transition" and "parallel", which operate in that order. The connections are changed automatically as the train accelerates. Upon starting, the motors are in series with each other and with all the resistance. The resistance is cut out in steps and the train accelerates to "full series" when all the resistance is out of circuit. The train may be running at about 30 km/h now. If full speed has been selected, the transition circuit will provide a parallel connection between the two legs of the series circuit. Immediately this is done, the two series connections will be opened and the resistances inserted back into each motor circuit. The resistances are then cut out in steps again until all are out of circuit. The motors are now running at "full parallel" and the train speed will rise to the design speed. During this whole process, the correct control sequence is maintained by the low voltage control circuit under the overall control of the driver selecting "shunt", "series" or "parallel" on his master controller. Field Weakening The DC motor can be made to run faster than the basic "balancing speed" achieved whilst in the full parallel configuration without any resistance in circuit. This is done by "field shunting". An additional circuit is provided in the motor field to weaken the current flowing through the field. The weakening is achieved by placing a resistance in parallel with the field. This has the effect of forcing the armature to speed up to restore the balance between its magnetic filed and that being produced in the field coils. It makes the train go faster.Various stages of field weakening can be employed, according to the design of the motor and the intended purpose. Some locomotives used as many as six steps of field weakening. Regenerative Braking Since the DC motor and a DC generator are virtually the same machine mechanically, it was immediately realised that a train could use its motors to act as generators and that this would provide some braking effect if a suitable way could be found to dispose of the energy. The idea formed that if the power could be returned to the source, other trains could use it. Trains were designed therefore, which could return current, generated during braking, to the supply system for use by other trains. Various schemes were tried over many years with more or less success but it was not until the adoption of modern electronics that reliable schemes have been available. Rheostatic Braking The major drawback with the regenerative braking system is that the line is not always able to accept the regenerated current. Some railways had substations fitted with giant resistors to absorb regenerated current not used by trains but this was a complex and not always reliable solution. As each train already had resistors, it was a logical step to use these to dispose of the generated current. The result was rheostatic braking. When the driver calls for brake, the power circuit connections to the motors are changed from their power configuration to a brake configuration and the resistors inserted into the motor circuit. As the motor generated energy is dispersed in the resistors and the train speed slows, the resistors are switched out in steps, just as they are during acceleration. Rheostatic braking on a DC motored train can be continued down to less than 20 mph when the friction brakes are used to bring the train to a stop. Before the advent of power electronics, there were some attempts to combine the two forms of what we now call "dynamic braking" so that the generated current would go to the power supply overhead line or third rail if it could be absorbed by other trains but diverted to on-board resistors if not. In the case of diesel-electric locomotives, dynamic braking is restricted to the rheostatic type. Racks of resistors can often be seen on the roofs of heavy-haul locomotives for which dynamic braking is a big advantage on long downhill grades where speed must be maintained at a restricted level for long periods. Originally derived from lift operation over a hundred years ago, multiple unit (MU) control has become the most common form of train control in use around the world today. This page describes how it started and its development in the century to date. See also Electric Traction, Electric Traction Drives, Electric Traction Glossary and Electronic Power. Contents Origins - The Relay - The Contactor - Multiple Unit Control - Forward and Reverse Origins Electric locomotives were originally designed so that the motors were controlled directly by the driver. The traction power circuits passed through a large controller mounted in the driving cab. A handle was rotated by the driver as necessary to change the switches in the circuit to increase or reduce power as required. This arrangement meant that the driver had to remain close to the motors if long and heavy, power-carrying cables were to be avoided. While this arrangement worked well enough, the desire to get rapid turnrounds on city streetcar railways led to the adoption of remote control. The idea was that, if the motors could be remotely controlled, a set of driver's controls could be placed at each end of the train. It would not be necessary to have a locomotive added at the rear of an arriving train to allow it to make the return journey. A cab would be installed at each end of the train and the driver just had to change ends to change direction. Once this idea was established, it was realised that the motors could be placed anywhere along the train, with as many or as few as required to provide the performance desired. With this development, more but smaller motors were scattered along the train instead of building a few large motors in a locomotive. This is how the concept of motor cars and trailer cars evolved. Trailer cars are just passenger carrying vehicles but motor cars are passenger carrying vehicles which have motors and their associated control equipment. Multiple unit trains, as these trains became known, were equipped with control cables called train lines, which connected the driver's controls with the motor controls and power switches on each motor car. The opening and closing of the power switches was achieved by electro-magnetic relays, using principles originally designed for lifts. While the idea was being established on passenger trains, it was also adopted on locomotives. It quickly became the standard method of control. The Relay The diagram below shows how a relay operates. A relay is really a remotely controlled switch. In the diagram left, a power circuit contains a switch which is opened and closed by operation of a relay. The relay is activated by a magnetic core which is energised when a controlling switch is closed. As the core is energised, it lifts and closes a pair of contacts in a second circuit - usually a power circuit. The current required for the relay is usually much lower than that used for the power circuit so it can be provided by a battery. In the diagram, the controlling switch is open, so the relay is de-energised and the power circuit contacts are open. If the controlling switch is closed, as in the right hand diagram, the relay is therefore energised and its core magnet lifts to close the contacts in the power circuit.Applied to a simple lift operating between two levels, a control switch on each landing could use relays to switch on the lift motor to move the lift up or down. On a train, the controlling switch could be located anywhere on the train to activate the relays controlling the power to the motors. The same principles can be used to carry out any other switching e.g. for lights or heating. It represents a safe and simple way of transmitting commands to a number of equipments in a train and it is the foundation upon which multiple unit control was based. On modern rolling stock, the relay is being replaced in many applications by electronic control, which speeds operation, eliminates the mechanical movements required and allows the miniaturisation of control systems. The Contactor As we have seen from the description above, the relay must have a current applied to it all the time it is required to be closed. To avoid having current on to, say, a lighting control relay all the time, a different type of remotely controlled switch is used. This is called a contactor. The contactor is really a latched relay. It can also be called (in the US) a "momentary switch". It only requires current to be on for a "moment" for it to operate. In order to keep the contacts closed once the control current is lost, the power circuit contacts are held in position by a mechanical latch. When it is necessary to open the power circuit, the latch is released and the contacts drop open.The contactor is operated by two coils, each with their own controlling switch. In this case, the contactor is closed or "set" by pressing the ON button and opened, or "tripped" by pressing the OFF button. Both ON and OFF buttons are sprung so that only a momentary current is used to activate the coil.Contactors are widely used on trains and, for us, are a good example to demonstrate how multiple unit control works in practice. Multiple Unit Control The following diagram illustrates the principal of multiple unit (MU) control as applied to a 3-car train. In the diagram (left), the lighting on each car is switched on and off by a lighting contactor. The contactor is latched closed when its "set" coil is energised or opened by the "trip" coil to unlatch it when required to switch off the lighting. All the lighting contactors on the train are connected to train wires, in this case one for "lights on" (in black) and one for "lights off" (in blue). The ON and OFF buttons are in the driving cabs at each end of the train so, the lighting can be switched on or off from either end of the train. To prevent unauthorised use of the control buttons, most of the important circuits in the cab are isolated by a "control switch" or "cab on switch". This is key operated and keys are only issued to qualified drivers or maintainers. It also means that, in our example, lights can only be switched on or off from one end at a time. The same principle, using contactors or relays, is applied to all other systems on the train - driving controls, braking control, heaters, doors, air conditioning, public address etc.Of course, current for the equipment on each vehicle, as in this case, lighting, comes from a separate source - the auxiliary supplies - in the form of a battery, an alternator, an inverter or a power train line. Forward and Reverse How, one might ask, does one ensure that a number of locomotives or EMUs (or DMUs for that matter), coupled together to work in multiple, perhaps facing in different directions, will all respond to the driver's command to go in the same direction, say forward, from the cab where he is sitting? How do you prevent one locomotive taking off in the wrong direction? Well, it's built in to the wiring and it's simple, as shown in this diagram. Each power unit (whether it be a locomotive or EMU) has a forward wire and a reverse wire connected to a "Forward and Reverse" switch of one sort or another in the cab. Looking at Unit 1, if the driver selects "Forward", the forward wire (in red) is energised and the "forward relay" (the arrow shows the direction of movement obtained for each relay) is energised to make the locomotive move in the forward direction. To ensure the correct direction is achieved by a second locomotive (Unit 2) that is coupled to the first, the forward and reverse wires are crossed over in the jumper cable. If the second locomotive faces in the opposite direction to the first, its reverse wire (shown in black here) will be energised to make the loco run in the same direction as its partner. To make sure this always happens, all multiple unit control jumpers have their forward and reverse wires crossed. But, you might ask, what if the locos both face in the same direction? You don't need the crossed wires in the jumper. The crossed wires in the jumper will make the second loco go the opposite way. No, that's been solved too. So that the same jumper with the crossed wires can be used anywhere, the forward and reverse wires are also crossed ON each locomotive, only at one end, usually near the jumper socket. Now, no matter which way round the locos are coupled to each other, and in what order, the forward command will always make all units drive in the same direction and the reverse command will make all units drive in the opposite direction.One final point. The jumper heads are designed so that they can only be inserted one way into the coupler socket on the locomotive, rather like a mouse plug on a computer. Modern Control Systems Modern systems use single wires or even fibre optic cables for controls. The system is sometimes referred to as "multiplixing", where a number of control signals are sent along a single wire. Some administrations require hard wired controls for safety systems like train braking but diverse programming can be used to make this redundant. Introduction This page describes the way electric motors on locomotives and multiple units drive the axles and wheels. See also the Electronic Power, Multiple Unit Operation, DC Traction Motor Systems and Electric Traction Glossary pages. Contents The DC Traction Motor: How it Drives the Axle - AC and DC Motors - Nose Suspended Motor - Quill Drive - Monomotor Bogie- Linear Motor The DC Traction Motor: How it Drives the Axle The traditional DC (Direct Current) electric motor driving a train or locomotive is a simple machine consisting of a case containing a fixed electrical part, the stator (called the stator because it is static and comprising what is called the field coils) and a moving electrical part, the rotor (because it rotates) or armature as it is often called. As the rotor turns, it turns a pinion which drives a gearwheel. The gearwheel is shrunk onto the axle and thus drives the wheels as shown in the diagram above.The motion of the motor is created by the interaction of the magnetism caused by the currents flowing the the stator and the rotor. This interaction causes the rotor to turn and provide the drive. The stator and the rotor of the DC motor are connected electrically. The connection consists of fixed, carbon brushes which are spring loaded so that they remain in contact with an extension of the armature called the commutator. In this way, the field coils (the stator) are kept in the circuit with the rotor (the armature and commutator). AC and DC Motors Both AC (Alternating Current) and DC motors have the same basic structure but there are differences and, for various reasons, the DC motor was originally the preferred form of motor for railway applications and most systems used it. Nowadays, modern power electronics has allowed the use of AC motors and, for most new equipments built today, the AC motor is the type used. Often, people ask about the differences between AC and DC motors as used in locomotives and multiple-units. In the early days of electric traction at the beginning of this century both types were tried. The limits of the technology at the time favoured the DC motor. It provided the right torque characteristic for railway operation and was reasonably simple to control. By the early 1980s, power electronics had progressed to the stage where the 3-phase AC motor became a serious and more efficient alternative to the DC motor because: 1. They are simpler to construct, they require no mechanical contacts to work (such as brushes) and they are lighter than DC motors for equivalent power. 2. Modern electronics allow AC motors to be controlled effectively to improve both adhesion and traction. 3. AC motors can be microprocessor controlled to a fine degree and can regenerate current down to almost a stop whereas DC regeneration fades quickly at low speeds. 4. They are more robust and easier to maintain than DC motors. This type of motor is commonly called the Asynchronous Motor and was often referred to as the squirrel cage motor on account of its early design form. The photos below show a DC and an AC motor. DC traction motor brushes Modern AC traction motor The DC motor is similar to look at externally but there are differences in construction, particularly because the DC motor has a commutator and brushes which the AC motor does not. Nose Suspended Motor The following diagram shows the layout of the traditional DC motor mounted in a bogie as a "nose suspended motor". In electric trains or locomotives, the DC motor was traditionally mounted in the bogie frame supported partially by the axle which it drove and partially by the bogie frame. The motor case was provided with a "nose" which rested on a bracket fixed to the transom of the bogie. It was called a "nose suspended motor" (see diagram above) and is still common around the world. Its main disadvantage is that part of the weight rests on the axle and is therefore unsprung. This leads to greater wear on bogie and track. Nowadays, designers try to ensure all the motor weight is sprung by ensuring it is carried entirely by the bogie frame - a frame mounted motor. Quill Drive This is a simplified diagram of a quill drive. A quill is described in the dictionary as, "the hollow stem of a feather" and "a bobbin or spindle", as well as a "feather" and, alternatively, what a porcupine has on its back. In railway traction terms, a quill drive is where a hollow shaft is placed round the driving axle and the motor drives the quill rather than driving the axle as it does with a nose suspended drive. The quill itself is attached, at one end, to one of the wheels by means of rubber bushed links and, at the other end, to the gearwheel by similar links. The big advantage of such drives is that all the weight of the motor is carried in the bogie frame (so it is a frame mounted motor) instead of it being directly supported by the axle and therefore partially unsprung. An example of a traction motor with quill drive appears in the following photo. Click on it for a full size view and the part names. Various forms of quill drive have been used over the years. Older versions used radially mounted coil steel springs instead of rubber to connect the links to the wheels. Some, like the example shown here, have the motor mounted parallel with the axle. Others have the motor at a right angle to the axle, as in the the UK Class 91 electric locomotives.In German the quill is called "Hohlwelle" (hollow shaft) and used in the ICE1 and ICE2 as well as the electric locomotive Class 101. (Source Tobias Benjamin Koehler 19 Oct 98). Monomotor Bogie As its name implies, the monomotor bogie has a single motor which drives both axles. Click on the thumbnail to see a photo with the part names.The design is much favoured in France, where it was introduced in the 1950s for the rubber tyred trainconcept. The motor is mounted longitudinally in the centre of the bogie and drives each axle through a differential gearbox, similar to a road vehicle. The differential gears are required to compensate for the operation of the rubber tyres round curves. It requires a special bogie frame construction to accommodate the motor.Another version of the monomotor bogie has also been applied to a number of French locomotive designs but here the arrangement is more conventional. Each bogie has a single motor mounted transversely over the centre as shown in the diagram left. The motor is fully suspended in the bogie frame and drives both axles through the gear train, which is contained in a single, large, oil filled gearcase (not shown). This type of drive is referred to in the locomotive wheel arrangement called a B-B, as opposed to a more conventional locomotive with four motors, each driving its own axle, which is called a Bo-Bo. Linear Motor A new form of traction which has appeared in recent years is the linear motor. The principal, compared with a standard motor, is shown here. This simple diagram shows the principal of the linear motor. The conventional DC motorconsists of a fixed part (the stator) and a moving part (the rotor). Both parts are contained in a case on the train and the rotor is connected to the axle by a pinion/gear arrangement. When the armature turns, the wheel turns.The two parts of the linear motor are separated and one is placed on the train and the other on the the track. Both parts are unwrapped and they are swapped so that the fixed part of the DC motor becomes the moving part of the linear motor mounted on the train while the former moving part of the DC motor is fixed to the track. The electro-magnetic interaction between the current in the fixed part and that in the moving part causes the train to be drawn along the line. There is a very small air gap (about 10 mm) between the two parts as shown in this photo. The efficiency of the linear motor is about 60% of the conventional motor but it has the advantage of less moving parts and it does not have the reliance on adhesion of the conventional motor. Introduction This page offers a selection of terms used in electric locomotive traction. If you can't find it here, try our Modern Railway Glossary page or use the Search facility. There are more Articles on Electric Traction on this site as follows: Electric Traction Power Supplies - DC Traction Motor Systems - Electric Traction Drives - Multiple Unit Operation - Electronic Power for Traction Electric Locomotive Parts Click on the part names for a description. This diagram shows an AC electric locomotive, i.e a locomotive collecting AC power from an overhead line. The red lines on the diagram indicate the single phase AC circuit, the green lines the DC circuits and the purple lines the 3-phase AC circuits. A locomotive using DC traction current is similar, except that there is no single phase AC circuit or transformer. The current passes directly from the pantograph (or shoe) to the main and auxiliary inverters. Asynchronous Motor Modern traction motor type using three phase AC electrical supply and now the favoured design for modern train traction systems. Can be used on DC and AC electrified railways with suitable control electronics and on diesel-electric locomotives. See the article on AC and DC Motors. Axle Brush The means by which the power supply circuit is completed with the substation once power has been drawn on the locomotive. Current collected from the overhead line or third rail is returned via the axle brush and one of the running rails. See also Power Supply - return. Balancing Speed See here for description. Battery All trains are provided with a battery to provide start up current and for supplying essential circuits, such as emergency lighting, when the line supply fails. The battery is usually connected across the DC control supply circuit. Bucholz Relay A device inserted in the oil cooling circuits of electric locomotive transformers to detect low oil pressure. In this event the relay trips out the power system. Often a source of spurious circuit breaker trips if not carefully calibrated. Camshaft Most DC electric traction power circuits use a camshaft to open or close the contactors controlling the resistances of the traction motor power circuit. The camshaft is driven by an electric motor or pneumatic cylinder. The cams on the shaft are arranged to ensure that the contactors open and close in the correct sequence. It is controlled by commands from the driver's cab and regulated by the fall of current in the motor circuit as each section of resistance is cut out in steps. The sound of this camshaft stepping can be heard under many older (pre electronics) trains as they accelerate. See also Notching Relay. Cannon Box Sleeve used to mount a traction motor on axle in electric power bogies and sometimes including an axle brush. Chopper Control A development in electric traction control which eliminates the need for power resistors by causing the voltage to the traction motors to be switched on and off (chopped) very rapidly during acceleration. It is accomplished by the use of thyristors and will give up to 20% improvement in efficiency over conventional resistance control. Circuit Breaker An electric train is almost always provided with some sort of circuit breaker to isolate the power supply when there is a fault, or for maintenance. On AC systems they are usually on the roof near the pantograph. There are two types - the air blast circuit breaker and the vacuum circuit breaker or VCB. The air or vacuum part is used to extinguish the arc which occurs as the two tips of the circuit breaker are opened. The VCB is popular in the UK and the air blast circuit breaker is more often seen on the continent of Europe. Contactor Similar to a relay in that it is a remotely operated switch used to control a higher power local circuit. The difference is that contactors normally latch or lock closed and have to be opened by a separate action. A lighting contactor will have two, low voltage operating coils, one to "set" the contactor closed to switch on the lights; the other to "trip" off the lights. Click here for diagrams and more detail. Converter Generic term for any solid state electronic system for converting alternating current to direct current or vice versa. Where an AC supply has to be converted to DC it is called a rectifier and where DC is converted to AC it is called an inverter. The word originated in the US but is now common elsewhere. Cooling Fans To keep the thyristors and other electronic power systems cool, the interior of a modern locomotive is equipped with an air management system, electronically controlled to keep all systems operating at the correct temperature. The fans are powered by an auxiliary inverter producing 3-phase AC at about 400 volts. Creep Control A form of electronically monitored acceleration control used very effectively on some modern drive systems which permits a certain degree of wheel slip to develop under maximum power application. A locomotive can develop maximum slow speed tractive effort if its wheels are turning between 5% and 15% faster than actually required by the train speed. DC Link Used on modern electronic power systems between the single phase rectifier and the 3-phase inverter. It is easier to convert the single phase AC from the overhead line to the 3-phase required for the motors by rectifying it to DC and then inverting the DC to 3-phase AC. Dynamic Braking A train braking system using the traction motors of the power vehicle(s) to act as generators which provide the braking effort. The power generated during braking is dissipated either as heat through on-board resistors (rheostatic braking) or by return to the traction supply line (regenerative braking). Most regenerative systems include on board resistors to allow rheostatic braking if the traction supply system is not receptive. The choice is automatically selected by the traction control system. See also the Dynamic Brake section of our Brakes Page. Earth Fault Relay See Ground Relay. Grid Train or locomotive mounted expanded steel resistor used to absorb excess electrical energy during motor or braking power control. Often seen on the roofs of diesel electric locomotives where they are used to dissipate heat during dynamic braking. Ground Relay An electrical relay provided in diesel and electric traction systems to protect the equipment against damage from earths and so-called "grounds". The result of such a relay operating is usually a shut-down of the electrical drive. Also sometimes called an Earth Fault Relay. GTO Thyristor Gate Turn Off thyristor, a thyristor which does not require a commutation (reverse flow circuit) circuit to switch it off. SeeThyristor IGBT Most recent power electronics development. It is replacing the GTO thyristor as it is smaller and requires less current to operate the switching sequences. See Transistor upon which the technology is based. Inverter Electronic power device mounted on trains to provide alternating current from direct current. Popular nowadays for DC railways to allow three phase drive or for auxiliary supplies which need an AC supply. See also converter with which it is often confused. Jerk Limit A means by which starting is smoothed by adjusting the rate of acceleration of a train by limiting the initial acceleration rate upon starting. It could be described as limiting the initial rate of change of acceleration. Also used in dynamic braking. Line Breaker Electro-mechanical switch in a traction motor power circuit used to activate or disable the circuit. It is normally closed to start the train and remains closed all the time power is required. It is opened by a command from the driving controller,no-volts detected, overload detected and (were required)wheel spin or slide detected. It is linked to the overload and no-volt control circuits so that it actually functions as a protective circuit breaker. Master Controller Driver's power control device located in the cab. The driver moves the handle of the master controller to apply or reduce power to the locomotive or train. Motor Blowers Traction motors on electric locomotives get very hot and, to keep their temperature at a reasonable level for long periods of hard work, they are usually fitted with electric fans called motor blowers. On a modern locomotive, they are powered by an auxiliary 3-phase AC supply of around 400 volts supplied by an auxiliary inverter. Notching Relay A DC motor power circuit relay which detects the rise and fall of current in the circuit and inhibits the operation of the resistance contactors during the acceleration sequence of automatically controlled motors. The relay operates a contactor stepping circuit so that, during acceleration of the motor, when the current falls, the relay detects the fall and calls for the next step of resistance to be switched out of the circuit. SeeDC Resistance Control and Camshaft. No-Volt Relay A power circuit relay which detected if power was lost for any reason and made sure that the control sequence was returned to the starting point before power could be re-applied. See Motor Protection. Overload Relay A power circuit relay which detected excessive current in the circuit and switched off the power to avoid damage to the motors. See Motor Protection above. Pantograph The current collection system used by locomotives and trains on routes electrified with overhead lines. The pantograph (often shortened to "pan") is held up by compressed air pressure. It is designed to collapse if it detects an obstruction. It can also be lowered manually to isolate the locomotive or train. Rectifier A converter consisting of thyristors and diodes which is used to convert AC to DC. A modern locomotive will usually have at least two, a "Main Rectifier" for the power circuits and one or more for the auxiliary circuits. Relay A remotely controlled switch which uses a low voltage control circuit. It will close (or open) a switch in a local circuit, usually of higher power. To see the principle of how it works, look here. See also Contactor. Resistance Control Method of traction motor control formerly almost universal on DC electric railways whereby the power to the motors was gradually increased from start up by removing resistances from the power circuit in steps. See more here. Originally this step control was done manually but it was later automatic, a relay in the circuit monitoring the rise and fall of current as the steps were removed. Many examples of this system still exist but new builds now use solid state control with power electronics. SEPEX Short form of SEParate EXcitement of traction motors where the armature and field coils of an electric motor are fed with independently controlled current. Click here for diagrams. This has been made much more useful since the introduction of thyristor control where motor control can be much more precise. SEPEX control also allows a degree of automatic wheel slip control during acceleration. Shoegear Equipment carried by a train and used for current collection on track mounted (third rail) power supply systems. Shoegear is usually mounted on the bogies close to the third rail. It is often equipped with devices to enable it to be retracted if required to isolate the car or on-board system which it supplies. See also the Power Supplypage. Synchronous Motor Traction motor where the field coils are mounted on the drive shaft and the armature coils in the housing, the inverse of normal practice. Favoured by the French and used on the high speed TGV Atlantique trains, this is a single-phase machine controlled by simple inverter. Now superseded by the asynchronous motor. Tap Changer Camshaft operated set of switches used on AC electric locomotives to control the voltage taken off the main transformer for traction motor power. Superseded by thyristor control. Thyristor A type of diode with a controlling gate which allows current to pass through it when the gate is energised. The gate is closed by the current being applied to the thyristor in the reverse direction. Thyristors (also referred to as choppers) are used for traction power control in place of resistance control systems. A GTO (Gate Turn Off) thyristor is a development in which current is turned off is by applying a pulse of current to the gate. Transformer A set of windings with a magnetic core used to step down or step up a voltage from one level to another. The voltage differences are determined by the proportion of windings on the input side compared with the proportion on the output side. An essential requirement for locomotives and trains using AC power, where the line voltage has to be stepped down before use on the train. Transistor The original electronic solid state device capable of controlling the amount of current flowing as well as switching it on and off. In the last few years, a powerful version has been applied to railway traction in the form of the Insulated Gate Bipolar Transistor (IGBT). Its principle advantage over the GTO Thyristor is its speed of switching and that its controls require much smaller current levels. Wheel Spin On a steam locomotive, the driver must reduce the steam admission to the cylinders by easing closed (or partially closed) the throttle/regulator when he hears the wheels start to spin. On diesel or electric locomotives, the current drawn by individual or groups of traction motors are compared - the motor (or group) which draws proportionally less amps than the others is deemed to be in a state of slip - and the power is reduced. Some systems - EMD Super Series for one - measure known wheel speed against ground speed as registered on a Doppler Radar. Many locomotives additionally use sand, which is applied to the wheel/rail contact point to improve adhesion - this is either controlled automatically, or manually by the driver (Foamer? No Way, 25 Apr 98). See also Wheel Spin Relay. Wheel Spin Relay (WSR) A relay in older traction motor control circuits used to detect wheel spin or slide by measuring the current levels in a pair of motors on a bogie and comparing them. The idea is to prevent motor damage by preventing an overspeeding motor causing an unacceptable rise in current in the other motor of the pair. If detected, the imbalance causes the control circuits to open the line breakers and reset the power control to the start position like a "no-volt" relay. This page describes the most recent developments of electric train power equipment including the latest IGBT controlled 3-phase Alternating Current (AC) motors and the new permanent magnet motor. Further pages on electric traction: - Multiple Unit Operation - Electric Traction Drives - DC Traction Motor Systems - Electric Traction Glossary Contents AC and DC Differences - AC Locomotives with DC Drives - The Diode - The Thyristor- SEPEX - DC Choppers - Dynamic Braking - The GTO Thyristor - AC Motors - The Asynchronous Motor - AC Drive - IGBT - Permanent Magnet Motor AC and DC Differences To understand the principles of modern traction power control systems, it is worth a look at the basics of DC and AC circuitry. DC is direct current - it travels in one direction only along a conductor. AC is alternating current - so called because it changes direction, flowing first one way along the conductor, then the other. It does this very rapidly. The number of times it changes direction per second is called the frequency and is measured in Hertz (Hz). It used to be called cycles per second, in case you've read of this in historical papers. In a diagrammatic representation, the two types of current appear as shown in the diagram above left. From a transmission point of view, AC is better than DC because it can be distributed at high voltages over a small size conductor wire, whereas DC needs a large, heavy wire or, on many DC railways, an extra rail. DC also needs more frequent feeder substations than AC - the ratio for a railway averages at about 8 to 1. It varies widely from one application to another but this gives a rough idea. See also Electric Traction Pages Power Supplies. Over the hundred years or so since the introduction of electric traction on railways, the rule has generally been that AC is used for longer distances and main lines and DC for shorter, suburban or metro lines. DC gets up to 3000 volts, while AC uses 15,000 - 50,000 volts. Until recently, DC motors have been the preferred type for railways because their characteristics were just right for the job. They were easy to control too. For this reason, even trains powered from AC supplies were usually equipped with DC motors. AC Locomotives with DC Drives This diagram (above) shows a simplified schematic for a 25 kV AC electric locomotive used in the UK from the late 1960s. The 25 kV AC is collected by the pantograph and passed to the transformer. The transformer is needed to step down the voltage to a level which can be managed by the traction motors. The level of current applied to the motors is controlled by a "tap changer", which switches in more sections of the transformer to increase the voltage passing through to the motors. It works in the same way as the resistance controllers used in DC traction, where the resistance contactors are controlled by a camshaft operating under the driver's commands. Before being passed to the motors, the AC has to be changed to DC by passing it through a rectifier. For the last 30 years, rectifiers have used diodes and their derivatives, the continuing development of which has led to the present, state-of-the-art AC traction systems. The Diode A diode is a device with no moving parts, known as a semi-conductor, which allows current to flow through it in one direction only. It will block any current which tries to flow in the opposite direction. Four diodes arranged in a bridge configuration, as shown below, use this property to convert AC into DC or to "rectify" it. It is called a "bridge rectifier". Diodes quickly became popular for railway applications because they represent a low maintenance option. They first appeared in the late 1960s when diode rectifiers were introduced on 25 kV AC electric locomotives. The Thyristor The thyristor is a development of the diode. It acts like a diode in that it allows current to flow in only one direction but differs from the diode in that it will only permit the current to flow after it has been switched on or "gated". Once it has been gated and the current is flowing, the only way it can be turned off is to send current in the opposite direction. This cancels the original gating command. It's simple to achieve on an AC locomotive because the current switches its direction during each cycle. With this development, controllable rectifiers became possible and tap changers quickly became history. A thyristor controlled version of the 25 kV AC electric locomotive traction system looks like the diagram here on the left. A tapping is taken off the transformer for each DC motor and each has its own controlling thyristors and diodes. The AC from the transformer is rectified to DC by chopping the cycles, so to speak, so that they appear in the raw as half cycles of AC as shown on the left. In reality, a smoothing circuit is added to remove most of the "ripple" and provide a more constant power flow as shown in the diagram (left). Meanwhile, the power level for the motor is controlled by varying the point in each rectified cycle at which the thyristors are fired. The later in the cycle the thyristor is gated, the lower the current available to the motor. As the gating is advanced, so the amount of current increases until the thyristors are "on" for the full cycle. This form of control is known as "phase angle control". SEPEX In more recent thyristor control systems, the motors themselves are wired differently from the old standard DC arrangement. The armatures and fields are no longer wired in series, they are wired separately - separate excitement, or SEPEX. Each field has its own thyristor, which is used to control the individual fields more precisely. Since the motors are separately excited, the acceleration sequence is carried out in two stages. In the first stage, the armature is fed current by its thyristors until it reaches the full voltage. This might give about 25% of the locomotive's full speed. In the second stage, the field thyristors are used to weaken the field current, forcing the motor to speed up to compensate. This technique is known as field weakening and was already used in pre-electronic applications. A big advantage of SEPEX is that wheel slip can be detected and corrected quickly, instead of the traditional method of either letting the wheels spin until the driver noticed or using a wheel slip relay to switch off the circuit and then restart it. DC Choppers The traditional resistance control of DC motors wastes current because it is drawn from the line (overhead or third rail) and only some is used to accelerate the train to 20-25 mph when, at last, full voltage is applied. The remainder is consumed in the resistances. Immediately thyristors were shown to work for AC traction, everyone began looking for a way to use them on DC systems. The problem was how to switch the thyristor off once it had been fired, in other words, how to get the reverse voltage to operate on an essentially one-way DC circuit. It is done by adding a "resonant circuit" using an inductor and a capacitor to force current to flow in the opposite direction to normal. This has the effect of switching off the thyristor, or "commutating" it. It is shown as part of the complete DC thyristor control circuit diagram (left). It has its own thyristor to switch it on when required. Two other features of the DC thyristor circuit are the "freewheel diode" and the "line filter". The freewheel diode keeps current circulating through the motor while the thyristor is off, using the motor's own electro magnetic inductance. Without the diode circuit, the current build up for the motor would be slower. Thyristor control can create a lot of electrical interference - with all that chopping, it's bound to. The "line filter" comprises a capacitor and an inductor and, as its name suggests, it is used to prevent interference from the train's power circuit getting into the supply system. The thyristor in DC traction applications controls the current applied to the motor by chopping it into segments, small ones at the beginning of the acceleration process, gradually enlarging as speed increases. This chopping of the circuit gave rise to the nickname "chopper control". It is visually represented by the diagram below, where the "ON" time of the thyristor is regulated to control the average voltage in the motor circuit. If the "ON" time is increased, so does the average voltage and the motor speeds up. The system began to appear on UK EMUs during the 1980s. Dynamic Braking Trains equipped with thyristor control can readily use dynamic braking, where the motors become generators and feed the resulting current into an on-board resistance (rheostatic braking) or back into the supply system (regenerative braking). The circuits are reconfigured, usually by a "motor/brake switch" operated by a command from the driver, to allow the thyristors to control the current flow as the motors slow down. An advantage of the thyristor control circuitry is its ability to choose either regenerative or rheostatic braking simply by automatically detecting the state of receptivity of the line. So, when the regenerated voltage across the supply connection filter circuit reaches a preset upper limit, a thyristor fires to divert the current to the on-board resistor. The GTO Thyristor By the late 1980s, the thyristor had been developed to a stage where it could be turned off by a control circuit as well as turned on by one. This was the "gate turn off" or GTO thyristor. This meant that the thyristor commutating circuit could be eliminated for DC fed power circuits, a saving on several electronic devices for each circuit. Now thyristors could be turned on and off virtually at will and now a single thyristor could be used to control a DC motor. It is at this point that the conventional DC motor reached its ultimate state in the railway traction industry. Most systems now being built use AC motors. AC Motors There are two types of AC motor, synchronous and asynchronous. The synchronous motor has its field coils mounted on the drive shaft and the armature coils in the housing, the inverse of normal practice. The synchronous motor has been used in electric traction - the most well-known application being by the French in their TGV Atlantique train. This used a 25 kV AC supply, rectified to DC and then inverted back to AC for supply to the motor. It was designed before the GTO thyristor had been sufficiently developed for railway use and it used simple thyristors. The advantage for the synchronous motor in this application is that the motor produces the reverse voltages needed to turn off the thyristors. It was a good solution is its day but it was quickly overtaken by the second type of AC motor - the asynchronous motor - when GTO thyristors became available. The Asynchronous Motor The asynchronous motor, also called the induction motor, is an AC motor which comprises a rotor and a stator like the DC motor, but the AC motor does not need current to flow through the armature. The current flowing in the field coils forces the rotor to turn. However, it does have to have a three phase supply, i.e. one where AC has three conductors, each conducting at a point one third into the normal cycle period, as visually represented in the diagram on the left. The two big advantages of the 3-phase design are that, one, the motor has no brushes, since there is no electrical connection between the armature and the fields and, two, the armature can be made of steel laminations, instead of the large number of windings required in other motors. These features make it more robust and cheaper to build than a commutator motor. AC Drive Modern electronics has given us the AC drive. It has only become available with modern electronics because the speed of a 3-phase AC motor is determined by the frequency of its supply but, at the same time, the power has to be varied. The frequency used to be difficult to control and that is why, until the advent of modern electronics, AC motors were almost exclusively used in constant speed applications and were therefore unsuitable for railway operation. A modern railway 3-phase traction motor is controlled by feeding in three AC currents which interact to cause the machine to turn. The three phases are most easily provided by an inverter which supplies the three variable voltage, variable frequency (VVVF) motor inputs. The variations of the voltage and frequency are controlled electronically. The AC motor can be used by either an AC or DC traction supply system. In the case of AC supply (diagram left), the line voltage (say 25kV single phase) is fed into a transformer and a secondary winding is taken off for the rectifier which produces a DC output of say 1500 - 2000 volts depending on the application. This is then passed to the inverter which provides the controlled three phases to the traction motors. The connection between the rectifier and the inverter is called the DC link. This usually also supplies an output for the train's auxiliary circuits. All the thyristors are GTOs, including those in the rectifier, since they are now used to provide a more efficient output than is possible with the older thyristors. In addition, all the facilities of DC motor control are available, including dynamic braking, but are provided more efficiently and with less moving parts. Applied to a DC traction supply, the 3-phase set-up is even more simple, since it doesn't need a transformer or a rectifier. The DC line voltage is applied to the inverter, which provides the 3-phase motor control. Control of these systems is complex but it is all carried out by microprocessors. The control of the voltage pulses and the frequency has to be matched with the motor speed. The changes which occur during this process produce a set of characteristic buzzing noises which sound like the "gear changing" of a road vehicle and which can clearly be heard when riding on the motor car of an AC driven EMU. IGBT Having got AC drive using GTO thyristors universally accepted (well, almost) as the modern traction system to have, power electronics engineers have produced a new development. This is the IGBT or Insulated Gate Bipolar Transistor. The transistor was the forerunner of modern electronics, (remember transistor radios?) and it could be turned on or off like a thyristor but it doesn't need the high currents of the thyristor turn off. However it was, until very recently, only capable of handling very small currents measured in thousanths of amps. Now, the modern device, in the form of the IGBT, can handle thousands of amps and it has appeared in traction applications. A lower current version was first used instead of thyristors in auxiliary supply inverters in the early 1990s but a higher rated version has now entered service in the most recent AC traction drives. Its principle benefit is that it can switch a lot faster (three to four times faster) than GTOs. This reduces the current required and therefore the heat generated, giving smaller and lighter units. The faster switching also reduces the complex "gearing" of GTOs and makes for a much smoother and more even sounding acceleration buzz from under the train. With IGBTs, "gear changing" has gone. Permanent Magnet Motor The next development in electric motor design is the permanent magnet motor. This is a 3-phase AC asynchronous motor with the usual squirrel cage construction replaced by magnets fixed in the rotor. The motor requires a complex control system system but it can be up to 25% smaller than a conventional 3-phase motor for the same power rating. The design also gives lower operating temperatures so that rotor cooling isn't needed and the stator is a sealed unit with integral liquid cooling. By 2011, a number of different types of trains had been equipped with permanent magnet motors, including 25 AGV high speed train sets, trams in France and Prague and EMUs in Euroe and Japan. The reduced size is particularly attractive for low floor vehicles where hub motors can be an effective way of providing traction in a compact bogie. Development of motor design and the associated control systems continues and it is certain that the permanent magnet motor will be seen on more railways in the future. A good description of the motor by Stuart Hillmansen, Felix Schmid and Thomas Schmid is in Railway Gazette International, February 2011.
The motor works because, simply put, when a current is passed through the motor circuit, there is a reaction between the current in the field and the current in the armature which causes the armature to turn. The armature and the field are connected in series and the whole motor is referred to as "series wound".A series wound DC motor has a low resistance field and armature circuit. Because of this, when voltage is applied to it, the current is high. (Ohms Law: current = voltage/resistance). The advantage of high current is that the magnetic fields inside the motor are strong, producing high torque (turning force), so it is ideal for starting a train. The disadvantage is that the current flowing into the motor has to be limited somehow, otherwise the supply could be overloaded and/or the motor and its cabling could be damaged. At best, the torque would exceed the adhesion and the driving wheels would slip. Traditionally, resistors were used to limit the initial current. DC Resistance Control As the DC motor starts to turn, the interaction of the magnetic fields inside it causes it to generate a voltage internally. This "back voltage" opposes the applied voltage and the current that flows is governed by the difference between the two. So, as the motor speeds up, the internally generated voltage rises, the effective voltage falls, less current is forced through the motor and thus the torque falls. The motor naturally stops acceleratingwhen the drag of the train matches the torque produced by the motors. To continue accelerating the train, resistors are switched out in steps, each step increasing the effective voltage and thus the current and torque for a little bit longer until the motor catches up. This can be heard and felt in older DC trains as a series of clunks under the floor, each accompanied by a jerk of acceleration as the torque suddenly increases in response to the new surge of current. When no resistor is left in the circuit, the full line voltage is applied directly to the motor. The train's speed remains constant at the point where the torque of the motor, governed by the effective voltage, equals the drag - sometimes referred to as balancing speed. If the train starts to climb a grade, the speed reduces because drag is greater than torque. But the reduction in speed causes the back voltage to decline and thus the effective voltage rises - until the current forced through the motor produces enough torque to match the new drag. On an electric train, the driver originally had to control the cutting out of resistance manually but, by the beginning of the First World War in 1914, automatic acceleration was being used in the UK on multiple-unit trains. This was achieved by an accelerating relay (often called a "notching relay") in the motor circuit (see next diagram below) which monitored the fall of current as each step of resistance was cut out. All the driver had to do was select low, medium or full speed (called "shunt", "series" and "parallel" from the way the motors were connected in the resistance circuit) and the equipment would do the rest. Motor Control and Protection As we have seen, DC motors are controlled by a "notching relay" set into the power circuit. But there are other relays provided for motor protection. Sharp spikes of current will quickly damage a DC motor so protective equipment is provided in the form of an "overload relay", which detects excessive current in the circuit and, when it occurs, switches off the power to avoid damage to the motors. Power is switched off by means of Line Breakers, one or two heavy-duty switches similar to circuit breakers which are remotely controlled. They would normally be opened or closed by the action of the driver's controller but they can also be opened automatically by the action of the overload relay.On a historical note, early equipment (pre-1905) had a huge fuse instead of an overload relay. Some of these lasted into the 1970s and I recall the complications of changing one, which involved inserting a wooden board (called a "paddle") between the shoes and the current rail. This was to isolate the current from the locomotive while you changed the fuse.A further protective device is also provided in the classic DC motor control circuit. This is the "no-volt" relay, which detects power lost for any reason and makes sure that the control sequence is returned to the starting point (i.e. all the resistances are restored to the power circuit) before power could be re-applied. This is necessary to ensure that too much current is not applied to a motor which lost speed while current was off. DC Power Circuit This diagram shows a simple traction motor power control circuit. Most DC motor circuits are arranged to control two or four motors. The control range is enhanced by changing the connections to the motors as the train accelerates. The system is known as "series-parallel control". Series-Parallel Control This diagram shows the principle of series-parallel control. There are three stages, "series", "transition" and "parallel", which operate in that order. The connections are changed automatically as the train accelerates. Upon starting, the motors are in series with each other and with all the resistance. The resistance is cut out in steps and the train accelerates to "full series" when all the resistance is out of circuit. The train may be running at about 30 km/h now. If full speed has been selected, the transition circuit will provide a parallel connection between the two legs of the series circuit. Immediately this is done, the two series connections will be opened and the resistances inserted back into each motor circuit. The resistances are then cut out in steps again until all are out of circuit. The motors are now running at "full parallel" and the train speed will rise to the design speed. During this whole process, the correct control sequence is maintained by the low voltage control circuit under the overall control of the driver selecting "shunt", "series" or "parallel" on his master controller. Field Weakening The DC motor can be made to run faster than the basic "balancing speed" achieved whilst in the full parallel configuration without any resistance in circuit. This is done by "field shunting". An additional circuit is provided in the motor field to weaken the current flowing through the field. The weakening is achieved by placing a resistance in parallel with the field. This has the effect of forcing the armature to speed up to restore the balance between its magnetic filed and that being produced in the field coils. It makes the train go faster.Various stages of field weakening can be employed, according to the design of the motor and the intended purpose. Some locomotives used as many as six steps of field weakening. Regenerative Braking Since the DC motor and a DC generator are virtually the same machine mechanically, it was immediately realised that a train could use its motors to act as generators and that this would provide some braking effect if a suitable way could be found to dispose of the energy. The idea formed that if the power could be returned to the source, other trains could use it. Trains were designed therefore, which could return current, generated during braking, to the supply system for use by other trains. Various schemes were tried over many years with more or less success but it was not until the adoption of modern electronics that reliable schemes have been available. Rheostatic Braking The major drawback with the regenerative braking system is that the line is not always able to accept the regenerated current. Some railways had substations fitted with giant resistors to absorb regenerated current not used by trains but this was a complex and not always reliable solution. As each train already had resistors, it was a logical step to use these to dispose of the generated current. The result was rheostatic braking. When the driver calls for brake, the power circuit connections to the motors are changed from their power configuration to a brake configuration and the resistors inserted into the motor circuit. As the motor generated energy is dispersed in the resistors and the train speed slows, the resistors are switched out in steps, just as they are during acceleration. Rheostatic braking on a DC motored train can be continued down to less than 20 mph when the friction brakes are used to bring the train to a stop. Before the advent of power electronics, there were some attempts to combine the two forms of what we now call "dynamic braking" so that the generated current would go to the power supply overhead line or third rail if it could be absorbed by other trains but diverted to on-board resistors if not. In the case of diesel-electric locomotives, dynamic braking is restricted to the rheostatic type. Racks of resistors can often be seen on the roofs of heavy-haul locomotives for which dynamic braking is a big advantage on long downhill grades where speed must be maintained at a restricted level for long periods. Originally derived from lift operation over a hundred years ago, multiple unit (MU) control has become the most common form of train control in use around the world today. This page describes how it started and its development in the century to date. See also Electric Traction, Electric Traction Drives, Electric Traction Glossary and Electronic Power. Contents Origins - The Relay - The Contactor - Multiple Unit Control - Forward and Reverse Origins Electric locomotives were originally designed so that the motors were controlled directly by the driver. The traction power circuits passed through a large controller mounted in the driving cab. A handle was rotated by the driver as necessary to change the switches in the circuit to increase or reduce power as required. This arrangement meant that the driver had to remain close to the motors if long and heavy, power-carrying cables were to be avoided. While this arrangement worked well enough, the desire to get rapid turnrounds on city streetcar railways led to the adoption of remote control. The idea was that, if the motors could be remotely controlled, a set of driver's controls could be placed at each end of the train. It would not be necessary to have a locomotive added at the rear of an arriving train to allow it to make the return journey. A cab would be installed at each end of the train and the driver just had to change ends to change direction. Once this idea was established, it was realised that the motors could be placed anywhere along the train, with as many or as few as required to provide the performance desired. With this development, more but smaller motors were scattered along the train instead of building a few large motors in a locomotive. This is how the concept of motor cars and trailer cars evolved. Trailer cars are just passenger carrying vehicles but motor cars are passenger carrying vehicles which have motors and their associated control equipment. Multiple unit trains, as these trains became known, were equipped with control cables called train lines, which connected the driver's controls with the motor controls and power switches on each motor car. The opening and closing of the power switches was achieved by electro-magnetic relays, using principles originally designed for lifts. While the idea was being established on passenger trains, it was also adopted on locomotives. It quickly became the standard method of control. The Relay The diagram below shows how a relay operates. A relay is really a remotely controlled switch. In the diagram left, a power circuit contains a switch which is opened and closed by operation of a relay. The relay is activated by a magnetic core which is energised when a controlling switch is closed. As the core is energised, it lifts and closes a pair of contacts in a second circuit - usually a power circuit. The current required for the relay is usually much lower than that used for the power circuit so it can be provided by a battery. In the diagram, the controlling switch is open, so the relay is de-energised and the power circuit contacts are open. If the controlling switch is closed, as in the right hand diagram, the relay is therefore energised and its core magnet lifts to close the contacts in the power circuit.Applied to a simple lift operating between two levels, a control switch on each landing could use relays to switch on the lift motor to move the lift up or down. On a train, the controlling switch could be located anywhere on the train to activate the relays controlling the power to the motors. The same principles can be used to carry out any other switching e.g. for lights or heating. It represents a safe and simple way of transmitting commands to a number of equipments in a train and it is the foundation upon which multiple unit control was based. On modern rolling stock, the relay is being replaced in many applications by electronic control, which speeds operation, eliminates the mechanical movements required and allows the miniaturisation of control systems. The Contactor As we have seen from the description above, the relay must have a current applied to it all the time it is required to be closed. To avoid having current on to, say, a lighting control relay all the time, a different type of remotely controlled switch is used. This is called a contactor. The contactor is really a latched relay. It can also be called (in the US) a "momentary switch". It only requires current to be on for a "moment" for it to operate. In order to keep the contacts closed once the control current is lost, the power circuit contacts are held in position by a mechanical latch. When it is necessary to open the power circuit, the latch is released and the contacts drop open.The contactor is operated by two coils, each with their own controlling switch. In this case, the contactor is closed or "set" by pressing the ON button and opened, or "tripped" by pressing the OFF button. Both ON and OFF buttons are sprung so that only a momentary current is used to activate the coil.Contactors are widely used on trains and, for us, are a good example to demonstrate how multiple unit control works in practice. Multiple Unit Control The following diagram illustrates the principal of multiple unit (MU) control as applied to a 3-car train. In the diagram (left), the lighting on each car is switched on and off by a lighting contactor. The contactor is latched closed when its "set" coil is energised or opened by the "trip" coil to unlatch it when required to switch off the lighting. All the lighting contactors on the train are connected to train wires, in this case one for "lights on" (in black) and one for "lights off" (in blue). The ON and OFF buttons are in the driving cabs at each end of the train so, the lighting can be switched on or off from either end of the train. To prevent unauthorised use of the control buttons, most of the important circuits in the cab are isolated by a "control switch" or "cab on switch". This is key operated and keys are only issued to qualified drivers or maintainers. It also means that, in our example, lights can only be switched on or off from one end at a time. The same principle, using contactors or relays, is applied to all other systems on the train - driving controls, braking control, heaters, doors, air conditioning, public address etc.Of course, current for the equipment on each vehicle, as in this case, lighting, comes from a separate source - the auxiliary supplies - in the form of a battery, an alternator, an inverter or a power train line. Forward and Reverse How, one might ask, does one ensure that a number of locomotives or EMUs (or DMUs for that matter), coupled together to work in multiple, perhaps facing in different directions, will all respond to the driver's command to go in the same direction, say forward, from the cab where he is sitting? How do you prevent one locomotive taking off in the wrong direction? Well, it's built in to the wiring and it's simple, as shown in this diagram. Each power unit (whether it be a locomotive or EMU) has a forward wire and a reverse wire connected to a "Forward and Reverse" switch of one sort or another in the cab. Looking at Unit 1, if the driver selects "Forward", the forward wire (in red) is energised and the "forward relay" (the arrow shows the direction of movement obtained for each relay) is energised to make the locomotive move in the forward direction. To ensure the correct direction is achieved by a second locomotive (Unit 2) that is coupled to the first, the forward and reverse wires are crossed over in the jumper cable. If the second locomotive faces in the opposite direction to the first, its reverse wire (shown in black here) will be energised to make the loco run in the same direction as its partner. To make sure this always happens, all multiple unit control jumpers have their forward and reverse wires crossed. But, you might ask, what if the locos both face in the same direction? You don't need the crossed wires in the jumper. The crossed wires in the jumper will make the second loco go the opposite way. No, that's been solved too. So that the same jumper with the crossed wires can be used anywhere, the forward and reverse wires are also crossed ON each locomotive, only at one end, usually near the jumper socket. Now, no matter which way round the locos are coupled to each other, and in what order, the forward command will always make all units drive in the same direction and the reverse command will make all units drive in the opposite direction.One final point. The jumper heads are designed so that they can only be inserted one way into the coupler socket on the locomotive, rather like a mouse plug on a computer. Modern Control Systems Modern systems use single wires or even fibre optic cables for controls. The system is sometimes referred to as "multiplixing", where a number of control signals are sent along a single wire. Some administrations require hard wired controls for safety systems like train braking but diverse programming can be used to make this redundant. Introduction This page describes the way electric motors on locomotives and multiple units drive the axles and wheels. See also the Electronic Power, Multiple Unit Operation, DC Traction Motor Systems and Electric Traction Glossary pages. Contents The DC Traction Motor: How it Drives the Axle - AC and DC Motors - Nose Suspended Motor - Quill Drive - Monomotor Bogie- Linear Motor The DC Traction Motor: How it Drives the Axle The traditional DC (Direct Current) electric motor driving a train or locomotive is a simple machine consisting of a case containing a fixed electrical part, the stator (called the stator because it is static and comprising what is called the field coils) and a moving electrical part, the rotor (because it rotates) or armature as it is often called. As the rotor turns, it turns a pinion which drives a gearwheel. The gearwheel is shrunk onto the axle and thus drives the wheels as shown in the diagram above.The motion of the motor is created by the interaction of the magnetism caused by the currents flowing the the stator and the rotor. This interaction causes the rotor to turn and provide the drive. The stator and the rotor of the DC motor are connected electrically. The connection consists of fixed, carbon brushes which are spring loaded so that they remain in contact with an extension of the armature called the commutator. In this way, the field coils (the stator) are kept in the circuit with the rotor (the armature and commutator). AC and DC Motors Both AC (Alternating Current) and DC motors have the same basic structure but there are differences and, for various reasons, the DC motor was originally the preferred form of motor for railway applications and most systems used it. Nowadays, modern power electronics has allowed the use of AC motors and, for most new equipments built today, the AC motor is the type used. Often, people ask about the differences between AC and DC motors as used in locomotives and multiple-units. In the early days of electric traction at the beginning of this century both types were tried. The limits of the technology at the time favoured the DC motor. It provided the right torque characteristic for railway operation and was reasonably simple to control. By the early 1980s, power electronics had progressed to the stage where the 3-phase AC motor became a serious and more efficient alternative to the DC motor because: 1. They are simpler to construct, they require no mechanical contacts to work (such as brushes) and they are lighter than DC motors for equivalent power. 2. Modern electronics allow AC motors to be controlled effectively to improve both adhesion and traction. 3. AC motors can be microprocessor controlled to a fine degree and can regenerate current down to almost a stop whereas DC regeneration fades quickly at low speeds. 4. They are more robust and easier to maintain than DC motors. This type of motor is commonly called the Asynchronous Motor and was often referred to as the squirrel cage motor on account of its early design form. The photos below show a DC and an AC motor. DC traction motor brushes Modern AC traction motor The DC motor is similar to look at externally but there are differences in construction, particularly because the DC motor has a commutator and brushes which the AC motor does not. Nose Suspended Motor The following diagram shows the layout of the traditional DC motor mounted in a bogie as a "nose suspended motor". In electric trains or locomotives, the DC motor was traditionally mounted in the bogie frame supported partially by the axle which it drove and partially by the bogie frame. The motor case was provided with a "nose" which rested on a bracket fixed to the transom of the bogie. It was called a "nose suspended motor" (see diagram above) and is still common around the world. Its main disadvantage is that part of the weight rests on the axle and is therefore unsprung. This leads to greater wear on bogie and track. Nowadays, designers try to ensure all the motor weight is sprung by ensuring it is carried entirely by the bogie frame - a frame mounted motor. Quill Drive This is a simplified diagram of a quill drive. A quill is described in the dictionary as, "the hollow stem of a feather" and "a bobbin or spindle", as well as a "feather" and, alternatively, what a porcupine has on its back. In railway traction terms, a quill drive is where a hollow shaft is placed round the driving axle and the motor drives the quill rather than driving the axle as it does with a nose suspended drive. The quill itself is attached, at one end, to one of the wheels by means of rubber bushed links and, at the other end, to the gearwheel by similar links. The big advantage of such drives is that all the weight of the motor is carried in the bogie frame (so it is a frame mounted motor) instead of it being directly supported by the axle and therefore partially unsprung. An example of a traction motor with quill drive appears in the following photo. Click on it for a full size view and the part names. Various forms of quill drive have been used over the years. Older versions used radially mounted coil steel springs instead of rubber to connect the links to the wheels. Some, like the example shown here, have the motor mounted parallel with the axle. Others have the motor at a right angle to the axle, as in the the UK Class 91 electric locomotives.In German the quill is called "Hohlwelle" (hollow shaft) and used in the ICE1 and ICE2 as well as the electric locomotive Class 101. (Source Tobias Benjamin Koehler 19 Oct 98). Monomotor Bogie As its name implies, the monomotor bogie has a single motor which drives both axles. Click on the thumbnail to see a photo with the part names.The design is much favoured in France, where it was introduced in the 1950s for the rubber tyred trainconcept. The motor is mounted longitudinally in the centre of the bogie and drives each axle through a differential gearbox, similar to a road vehicle. The differential gears are required to compensate for the operation of the rubber tyres round curves. It requires a special bogie frame construction to accommodate the motor.Another version of the monomotor bogie has also been applied to a number of French locomotive designs but here the arrangement is more conventional. Each bogie has a single motor mounted transversely over the centre as shown in the diagram left. The motor is fully suspended in the bogie frame and drives both axles through the gear train, which is contained in a single, large, oil filled gearcase (not shown). This type of drive is referred to in the locomotive wheel arrangement called a B-B, as opposed to a more conventional locomotive with four motors, each driving its own axle, which is called a Bo-Bo. Linear Motor A new form of traction which has appeared in recent years is the linear motor. The principal, compared with a standard motor, is shown here. This simple diagram shows the principal of the linear motor. The conventional DC motorconsists of a fixed part (the stator) and a moving part (the rotor). Both parts are contained in a case on the train and the rotor is connected to the axle by a pinion/gear arrangement. When the armature turns, the wheel turns.The two parts of the linear motor are separated and one is placed on the train and the other on the the track. Both parts are unwrapped and they are swapped so that the fixed part of the DC motor becomes the moving part of the linear motor mounted on the train while the former moving part of the DC motor is fixed to the track. The electro-magnetic interaction between the current in the fixed part and that in the moving part causes the train to be drawn along the line. There is a very small air gap (about 10 mm) between the two parts as shown in this photo. The efficiency of the linear motor is about 60% of the conventional motor but it has the advantage of less moving parts and it does not have the reliance on adhesion of the conventional motor. Introduction This page offers a selection of terms used in electric locomotive traction. If you can't find it here, try our Modern Railway Glossary page or use the Search facility. There are more Articles on Electric Traction on this site as follows: Electric Traction Power Supplies - DC Traction Motor Systems - Electric Traction Drives - Multiple Unit Operation - Electronic Power for Traction Electric Locomotive Parts Click on the part names for a description. This diagram shows an AC electric locomotive, i.e a locomotive collecting AC power from an overhead line. The red lines on the diagram indicate the single phase AC circuit, the green lines the DC circuits and the purple lines the 3-phase AC circuits. A locomotive using DC traction current is similar, except that there is no single phase AC circuit or transformer. The current passes directly from the pantograph (or shoe) to the main and auxiliary inverters. Asynchronous Motor Modern traction motor type using three phase AC electrical supply and now the favoured design for modern train traction systems. Can be used on DC and AC electrified railways with suitable control electronics and on diesel-electric locomotives. See the article on AC and DC Motors. Axle Brush The means by which the power supply circuit is completed with the substation once power has been drawn on the locomotive. Current collected from the overhead line or third rail is returned via the axle brush and one of the running rails. See also Power Supply - return. Balancing Speed See here for description. Battery All trains are provided with a battery to provide start up current and for supplying essential circuits, such as emergency lighting, when the line supply fails. The battery is usually connected across the DC control supply circuit. Bucholz Relay A device inserted in the oil cooling circuits of electric locomotive transformers to detect low oil pressure. In this event the relay trips out the power system. Often a source of spurious circuit breaker trips if not carefully calibrated. Camshaft Most DC electric traction power circuits use a camshaft to open or close the contactors controlling the resistances of the traction motor power circuit. The camshaft is driven by an electric motor or pneumatic cylinder. The cams on the shaft are arranged to ensure that the contactors open and close in the correct sequence. It is controlled by commands from the driver's cab and regulated by the fall of current in the motor circuit as each section of resistance is cut out in steps. The sound of this camshaft stepping can be heard under many older (pre electronics) trains as they accelerate. See also Notching Relay. Cannon Box Sleeve used to mount a traction motor on axle in electric power bogies and sometimes including an axle brush. Chopper Control A development in electric traction control which eliminates the need for power resistors by causing the voltage to the traction motors to be switched on and off (chopped) very rapidly during acceleration. It is accomplished by the use of thyristors and will give up to 20% improvement in efficiency over conventional resistance control. Circuit Breaker An electric train is almost always provided with some sort of circuit breaker to isolate the power supply when there is a fault, or for maintenance. On AC systems they are usually on the roof near the pantograph. There are two types - the air blast circuit breaker and the vacuum circuit breaker or VCB. The air or vacuum part is used to extinguish the arc which occurs as the two tips of the circuit breaker are opened. The VCB is popular in the UK and the air blast circuit breaker is more often seen on the continent of Europe. Contactor Similar to a relay in that it is a remotely operated switch used to control a higher power local circuit. The difference is that contactors normally latch or lock closed and have to be opened by a separate action. A lighting contactor will have two, low voltage operating coils, one to "set" the contactor closed to switch on the lights; the other to "trip" off the lights. Click here for diagrams and more detail. Converter Generic term for any solid state electronic system for converting alternating current to direct current or vice versa. Where an AC supply has to be converted to DC it is called a rectifier and where DC is converted to AC it is called an inverter. The word originated in the US but is now common elsewhere. Cooling Fans To keep the thyristors and other electronic power systems cool, the interior of a modern locomotive is equipped with an air management system, electronically controlled to keep all systems operating at the correct temperature. The fans are powered by an auxiliary inverter producing 3-phase AC at about 400 volts. Creep Control A form of electronically monitored acceleration control used very effectively on some modern drive systems which permits a certain degree of wheel slip to develop under maximum power application. A locomotive can develop maximum slow speed tractive effort if its wheels are turning between 5% and 15% faster than actually required by the train speed. DC Link Used on modern electronic power systems between the single phase rectifier and the 3-phase inverter. It is easier to convert the single phase AC from the overhead line to the 3-phase required for the motors by rectifying it to DC and then inverting the DC to 3-phase AC. Dynamic Braking A train braking system using the traction motors of the power vehicle(s) to act as generators which provide the braking effort. The power generated during braking is dissipated either as heat through on-board resistors (rheostatic braking) or by return to the traction supply line (regenerative braking). Most regenerative systems include on board resistors to allow rheostatic braking if the traction supply system is not receptive. The choice is automatically selected by the traction control system. See also the Dynamic Brake section of our Brakes Page. Earth Fault Relay See Ground Relay. Grid Train or locomotive mounted expanded steel resistor used to absorb excess electrical energy during motor or braking power control. Often seen on the roofs of diesel electric locomotives where they are used to dissipate heat during dynamic braking. Ground Relay An electrical relay provided in diesel and electric traction systems to protect the equipment against damage from earths and so-called "grounds". The result of such a relay operating is usually a shut-down of the electrical drive. Also sometimes called an Earth Fault Relay. GTO Thyristor Gate Turn Off thyristor, a thyristor which does not require a commutation (reverse flow circuit) circuit to switch it off. SeeThyristor IGBT Most recent power electronics development. It is replacing the GTO thyristor as it is smaller and requires less current to operate the switching sequences. See Transistor upon which the technology is based. Inverter Electronic power device mounted on trains to provide alternating current from direct current. Popular nowadays for DC railways to allow three phase drive or for auxiliary supplies which need an AC supply. See also converter with which it is often confused. Jerk Limit A means by which starting is smoothed by adjusting the rate of acceleration of a train by limiting the initial acceleration rate upon starting. It could be described as limiting the initial rate of change of acceleration. Also used in dynamic braking. Line Breaker Electro-mechanical switch in a traction motor power circuit used to activate or disable the circuit. It is normally closed to start the train and remains closed all the time power is required. It is opened by a command from the driving controller,no-volts detected, overload detected and (were required)wheel spin or slide detected. It is linked to the overload and no-volt control circuits so that it actually functions as a protective circuit breaker. Master Controller Driver's power control device located in the cab. The driver moves the handle of the master controller to apply or reduce power to the locomotive or train. Motor Blowers Traction motors on electric locomotives get very hot and, to keep their temperature at a reasonable level for long periods of hard work, they are usually fitted with electric fans called motor blowers. On a modern locomotive, they are powered by an auxiliary 3-phase AC supply of around 400 volts supplied by an auxiliary inverter. Notching Relay A DC motor power circuit relay which detects the rise and fall of current in the circuit and inhibits the operation of the resistance contactors during the acceleration sequence of automatically controlled motors. The relay operates a contactor stepping circuit so that, during acceleration of the motor, when the current falls, the relay detects the fall and calls for the next step of resistance to be switched out of the circuit. SeeDC Resistance Control and Camshaft. No-Volt Relay A power circuit relay which detected if power was lost for any reason and made sure that the control sequence was returned to the starting point before power could be re-applied. See Motor Protection. Overload Relay A power circuit relay which detected excessive current in the circuit and switched off the power to avoid damage to the motors. See Motor Protection above. Pantograph The current collection system used by locomotives and trains on routes electrified with overhead lines. The pantograph (often shortened to "pan") is held up by compressed air pressure. It is designed to collapse if it detects an obstruction. It can also be lowered manually to isolate the locomotive or train. Rectifier A converter consisting of thyristors and diodes which is used to convert AC to DC. A modern locomotive will usually have at least two, a "Main Rectifier" for the power circuits and one or more for the auxiliary circuits. Relay A remotely controlled switch which uses a low voltage control circuit. It will close (or open) a switch in a local circuit, usually of higher power. To see the principle of how it works, look here. See also Contactor. Resistance Control Method of traction motor control formerly almost universal on DC electric railways whereby the power to the motors was gradually increased from start up by removing resistances from the power circuit in steps. See more here. Originally this step control was done manually but it was later automatic, a relay in the circuit monitoring the rise and fall of current as the steps were removed. Many examples of this system still exist but new builds now use solid state control with power electronics. SEPEX Short form of SEParate EXcitement of traction motors where the armature and field coils of an electric motor are fed with independently controlled current. Click here for diagrams. This has been made much more useful since the introduction of thyristor control where motor control can be much more precise. SEPEX control also allows a degree of automatic wheel slip control during acceleration. Shoegear Equipment carried by a train and used for current collection on track mounted (third rail) power supply systems. Shoegear is usually mounted on the bogies close to the third rail. It is often equipped with devices to enable it to be retracted if required to isolate the car or on-board system which it supplies. See also the Power Supplypage. Synchronous Motor Traction motor where the field coils are mounted on the drive shaft and the armature coils in the housing, the inverse of normal practice. Favoured by the French and used on the high speed TGV Atlantique trains, this is a single-phase machine controlled by simple inverter. Now superseded by the asynchronous motor. Tap Changer Camshaft operated set of switches used on AC electric locomotives to control the voltage taken off the main transformer for traction motor power. Superseded by thyristor control. Thyristor A type of diode with a controlling gate which allows current to pass through it when the gate is energised. The gate is closed by the current being applied to the thyristor in the reverse direction. Thyristors (also referred to as choppers) are used for traction power control in place of resistance control systems. A GTO (Gate Turn Off) thyristor is a development in which current is turned off is by applying a pulse of current to the gate. Transformer A set of windings with a magnetic core used to step down or step up a voltage from one level to another. The voltage differences are determined by the proportion of windings on the input side compared with the proportion on the output side. An essential requirement for locomotives and trains using AC power, where the line voltage has to be stepped down before use on the train. Transistor The original electronic solid state device capable of controlling the amount of current flowing as well as switching it on and off. In the last few years, a powerful version has been applied to railway traction in the form of the Insulated Gate Bipolar Transistor (IGBT). Its principle advantage over the GTO Thyristor is its speed of switching and that its controls require much smaller current levels. Wheel Spin On a steam locomotive, the driver must reduce the steam admission to the cylinders by easing closed (or partially closed) the throttle/regulator when he hears the wheels start to spin. On diesel or electric locomotives, the current drawn by individual or groups of traction motors are compared - the motor (or group) which draws proportionally less amps than the others is deemed to be in a state of slip - and the power is reduced. Some systems - EMD Super Series for one - measure known wheel speed against ground speed as registered on a Doppler Radar. Many locomotives additionally use sand, which is applied to the wheel/rail contact point to improve adhesion - this is either controlled automatically, or manually by the driver (Foamer? No Way, 25 Apr 98). See also Wheel Spin Relay. Wheel Spin Relay (WSR) A relay in older traction motor control circuits used to detect wheel spin or slide by measuring the current levels in a pair of motors on a bogie and comparing them. The idea is to prevent motor damage by preventing an overspeeding motor causing an unacceptable rise in current in the other motor of the pair. If detected, the imbalance causes the control circuits to open the line breakers and reset the power control to the start position like a "no-volt" relay. This page describes the most recent developments of electric train power equipment including the latest IGBT controlled 3-phase Alternating Current (AC) motors and the new permanent magnet motor. Further pages on electric traction: - Multiple Unit Operation - Electric Traction Drives - DC Traction Motor Systems - Electric Traction Glossary Contents AC and DC Differences - AC Locomotives with DC Drives - The Diode - The Thyristor- SEPEX - DC Choppers - Dynamic Braking - The GTO Thyristor - AC Motors - The Asynchronous Motor - AC Drive - IGBT - Permanent Magnet Motor AC and DC Differences To understand the principles of modern traction power control systems, it is worth a look at the basics of DC and AC circuitry. DC is direct current - it travels in one direction only along a conductor. AC is alternating current - so called because it changes direction, flowing first one way along the conductor, then the other. It does this very rapidly. The number of times it changes direction per second is called the frequency and is measured in Hertz (Hz). It used to be called cycles per second, in case you've read of this in historical papers. In a diagrammatic representation, the two types of current appear as shown in the diagram above left. From a transmission point of view, AC is better than DC because it can be distributed at high voltages over a small size conductor wire, whereas DC needs a large, heavy wire or, on many DC railways, an extra rail. DC also needs more frequent feeder substations than AC - the ratio for a railway averages at about 8 to 1. It varies widely from one application to another but this gives a rough idea. See also Electric Traction Pages Power Supplies. Over the hundred years or so since the introduction of electric traction on railways, the rule has generally been that AC is used for longer distances and main lines and DC for shorter, suburban or metro lines. DC gets up to 3000 volts, while AC uses 15,000 - 50,000 volts. Until recently, DC motors have been the preferred type for railways because their characteristics were just right for the job. They were easy to control too. For this reason, even trains powered from AC supplies were usually equipped with DC motors. AC Locomotives with DC Drives This diagram (above) shows a simplified schematic for a 25 kV AC electric locomotive used in the UK from the late 1960s. The 25 kV AC is collected by the pantograph and passed to the transformer. The transformer is needed to step down the voltage to a level which can be managed by the traction motors. The level of current applied to the motors is controlled by a "tap changer", which switches in more sections of the transformer to increase the voltage passing through to the motors. It works in the same way as the resistance controllers used in DC traction, where the resistance contactors are controlled by a camshaft operating under the driver's commands. Before being passed to the motors, the AC has to be changed to DC by passing it through a rectifier. For the last 30 years, rectifiers have used diodes and their derivatives, the continuing development of which has led to the present, state-of-the-art AC traction systems. The Diode A diode is a device with no moving parts, known as a semi-conductor, which allows current to flow through it in one direction only. It will block any current which tries to flow in the opposite direction. Four diodes arranged in a bridge configuration, as shown below, use this property to convert AC into DC or to "rectify" it. It is called a "bridge rectifier". Diodes quickly became popular for railway applications because they represent a low maintenance option. They first appeared in the late 1960s when diode rectifiers were introduced on 25 kV AC electric locomotives. The Thyristor The thyristor is a development of the diode. It acts like a diode in that it allows current to flow in only one direction but differs from the diode in that it will only permit the current to flow after it has been switched on or "gated". Once it has been gated and the current is flowing, the only way it can be turned off is to send current in the opposite direction. This cancels the original gating command. It's simple to achieve on an AC locomotive because the current switches its direction during each cycle. With this development, controllable rectifiers became possible and tap changers quickly became history. A thyristor controlled version of the 25 kV AC electric locomotive traction system looks like the diagram here on the left. A tapping is taken off the transformer for each DC motor and each has its own controlling thyristors and diodes. The AC from the transformer is rectified to DC by chopping the cycles, so to speak, so that they appear in the raw as half cycles of AC as shown on the left. In reality, a smoothing circuit is added to remove most of the "ripple" and provide a more constant power flow as shown in the diagram (left). Meanwhile, the power level for the motor is controlled by varying the point in each rectified cycle at which the thyristors are fired. The later in the cycle the thyristor is gated, the lower the current available to the motor. As the gating is advanced, so the amount of current increases until the thyristors are "on" for the full cycle. This form of control is known as "phase angle control". SEPEX In more recent thyristor control systems, the motors themselves are wired differently from the old standard DC arrangement. The armatures and fields are no longer wired in series, they are wired separately - separate excitement, or SEPEX. Each field has its own thyristor, which is used to control the individual fields more precisely. Since the motors are separately excited, the acceleration sequence is carried out in two stages. In the first stage, the armature is fed current by its thyristors until it reaches the full voltage. This might give about 25% of the locomotive's full speed. In the second stage, the field thyristors are used to weaken the field current, forcing the motor to speed up to compensate. This technique is known as field weakening and was already used in pre-electronic applications. A big advantage of SEPEX is that wheel slip can be detected and corrected quickly, instead of the traditional method of either letting the wheels spin until the driver noticed or using a wheel slip relay to switch off the circuit and then restart it. DC Choppers The traditional resistance control of DC motors wastes current because it is drawn from the line (overhead or third rail) and only some is used to accelerate the train to 20-25 mph when, at last, full voltage is applied. The remainder is consumed in the resistances. Immediately thyristors were shown to work for AC traction, everyone began looking for a way to use them on DC systems. The problem was how to switch the thyristor off once it had been fired, in other words, how to get the reverse voltage to operate on an essentially one-way DC circuit. It is done by adding a "resonant circuit" using an inductor and a capacitor to force current to flow in the opposite direction to normal. This has the effect of switching off the thyristor, or "commutating" it. It is shown as part of the complete DC thyristor control circuit diagram (left). It has its own thyristor to switch it on when required. Two other features of the DC thyristor circuit are the "freewheel diode" and the "line filter". The freewheel diode keeps current circulating through the motor while the thyristor is off, using the motor's own electro magnetic inductance. Without the diode circuit, the current build up for the motor would be slower. Thyristor control can create a lot of electrical interference - with all that chopping, it's bound to. The "line filter" comprises a capacitor and an inductor and, as its name suggests, it is used to prevent interference from the train's power circuit getting into the supply system. The thyristor in DC traction applications controls the current applied to the motor by chopping it into segments, small ones at the beginning of the acceleration process, gradually enlarging as speed increases. This chopping of the circuit gave rise to the nickname "chopper control". It is visually represented by the diagram below, where the "ON" time of the thyristor is regulated to control the average voltage in the motor circuit. If the "ON" time is increased, so does the average voltage and the motor speeds up. The system began to appear on UK EMUs during the 1980s. Dynamic Braking Trains equipped with thyristor control can readily use dynamic braking, where the motors become generators and feed the resulting current into an on-board resistance (rheostatic braking) or back into the supply system (regenerative braking). The circuits are reconfigured, usually by a "motor/brake switch" operated by a command from the driver, to allow the thyristors to control the current flow as the motors slow down. An advantage of the thyristor control circuitry is its ability to choose either regenerative or rheostatic braking simply by automatically detecting the state of receptivity of the line. So, when the regenerated voltage across the supply connection filter circuit reaches a preset upper limit, a thyristor fires to divert the current to the on-board resistor. The GTO Thyristor By the late 1980s, the thyristor had been developed to a stage where it could be turned off by a control circuit as well as turned on by one. This was the "gate turn off" or GTO thyristor. This meant that the thyristor commutating circuit could be eliminated for DC fed power circuits, a saving on several electronic devices for each circuit. Now thyristors could be turned on and off virtually at will and now a single thyristor could be used to control a DC motor. It is at this point that the conventional DC motor reached its ultimate state in the railway traction industry. Most systems now being built use AC motors. AC Motors There are two types of AC motor, synchronous and asynchronous. The synchronous motor has its field coils mounted on the drive shaft and the armature coils in the housing, the inverse of normal practice. The synchronous motor has been used in electric traction - the most well-known application being by the French in their TGV Atlantique train. This used a 25 kV AC supply, rectified to DC and then inverted back to AC for supply to the motor. It was designed before the GTO thyristor had been sufficiently developed for railway use and it used simple thyristors. The advantage for the synchronous motor in this application is that the motor produces the reverse voltages needed to turn off the thyristors. It was a good solution is its day but it was quickly overtaken by the second type of AC motor - the asynchronous motor - when GTO thyristors became available. The Asynchronous Motor The asynchronous motor, also called the induction motor, is an AC motor which comprises a rotor and a stator like the DC motor, but the AC motor does not need current to flow through the armature. The current flowing in the field coils forces the rotor to turn. However, it does have to have a three phase supply, i.e. one where AC has three conductors, each conducting at a point one third into the normal cycle period, as visually represented in the diagram on the left. The two big advantages of the 3-phase design are that, one, the motor has no brushes, since there is no electrical connection between the armature and the fields and, two, the armature can be made of steel laminations, instead of the large number of windings required in other motors. These features make it more robust and cheaper to build than a commutator motor. AC Drive Modern electronics has given us the AC drive. It has only become available with modern electronics because the speed of a 3-phase AC motor is determined by the frequency of its supply but, at the same time, the power has to be varied. The frequency used to be difficult to control and that is why, until the advent of modern electronics, AC motors were almost exclusively used in constant speed applications and were therefore unsuitable for railway operation. A modern railway 3-phase traction motor is controlled by feeding in three AC currents which interact to cause the machine to turn. The three phases are most easily provided by an inverter which supplies the three variable voltage, variable frequency (VVVF) motor inputs. The variations of the voltage and frequency are controlled electronically. The AC motor can be used by either an AC or DC traction supply system. In the case of AC supply (diagram left), the line voltage (say 25kV single phase) is fed into a transformer and a secondary winding is taken off for the rectifier which produces a DC output of say 1500 - 2000 volts depending on the application. This is then passed to the inverter which provides the controlled three phases to the traction motors. The connection between the rectifier and the inverter is called the DC link. This usually also supplies an output for the train's auxiliary circuits. All the thyristors are GTOs, including those in the rectifier, since they are now used to provide a more efficient output than is possible with the older thyristors. In addition, all the facilities of DC motor control are available, including dynamic braking, but are provided more efficiently and with less moving parts. Applied to a DC traction supply, the 3-phase set-up is even more simple, since it doesn't need a transformer or a rectifier. The DC line voltage is applied to the inverter, which provides the 3-phase motor control. Control of these systems is complex but it is all carried out by microprocessors. The control of the voltage pulses and the frequency has to be matched with the motor speed. The changes which occur during this process produce a set of characteristic buzzing noises which sound like the "gear changing" of a road vehicle and which can clearly be heard when riding on the motor car of an AC driven EMU. IGBT Having got AC drive using GTO thyristors universally accepted (well, almost) as the modern traction system to have, power electronics engineers have produced a new development. This is the IGBT or Insulated Gate Bipolar Transistor. The transistor was the forerunner of modern electronics, (remember transistor radios?) and it could be turned on or off like a thyristor but it doesn't need the high currents of the thyristor turn off. However it was, until very recently, only capable of handling very small currents measured in thousanths of amps. Now, the modern device, in the form of the IGBT, can handle thousands of amps and it has appeared in traction applications. A lower current version was first used instead of thyristors in auxiliary supply inverters in the early 1990s but a higher rated version has now entered service in the most recent AC traction drives. Its principle benefit is that it can switch a lot faster (three to four times faster) than GTOs. This reduces the current required and therefore the heat generated, giving smaller and lighter units. The faster switching also reduces the complex "gearing" of GTOs and makes for a much smoother and more even sounding acceleration buzz from under the train. With IGBTs, "gear changing" has gone. Permanent Magnet Motor The next development in electric motor design is the permanent magnet motor. This is a 3-phase AC asynchronous motor with the usual squirrel cage construction replaced by magnets fixed in the rotor. The motor requires a complex control system system but it can be up to 25% smaller than a conventional 3-phase motor for the same power rating. The design also gives lower operating temperatures so that rotor cooling isn't needed and the stator is a sealed unit with integral liquid cooling. By 2011, a number of different types of trains had been equipped with permanent magnet motors, including 25 AGV high speed train sets, trams in France and Prague and EMUs in Euroe and Japan. The reduced size is particularly attractive for low floor vehicles where hub motors can be an effective way of providing traction in a compact bogie. Development of motor design and the associated control systems continues and it is certain that the permanent magnet motor will be seen on more railways in the future. A good description of the motor by Stuart Hillmansen, Felix Schmid and Thomas Schmid is in Railway Gazette International, February 2011.
+ نوشته شده در شنبه نهم دی ۱۳۹۱ ساعت ۸:۴۷ ب.ظ توسط Ahmad Esamili
|